Key Testing Data on VIG Load Resistance Performance Nears Completion
Developing a new ASTM load resistance standard
Above: Gund Hall, a concrete modernist building that has housed Harvard University’s Graduate Schol of Design since 1972, features a new, high-performance façade thanks to vacuum insulating glass provided by Vitro Architectural Glass. Photo by Tom Kessler.
The National Glass Association and the Fenestration and Glazing Industry Alliance are collaborating to test the load resistance and deflection characteristics of vacuum insulating glass in order to help develop a new ASTM load resistance standard: WK83445, “Standard Practice for Determining Load Resistance of Vacuum Insulating Glass in Buildings.”
The goal is to create loading charts and engineering tools for VIG similar to those found in ASTM E1300, “Standard Practice for Determining Load Resistance of Glass in Buildings.” The testing will help architects and engineers determine the load capacity of VIG units, understand how VIG deflects under pressure and ensure safe use of VIG in buildings subject to wind, snow and other environmental loads. Filling this critical gap in industry knowledge on VIG performance will ultimately enable more reliable specifications and support broader market acceptance of the technology.
While VIG offers exceptional thermal performance and a slim glass profile, the current dearth of testing data is making it more challenging for architects and engineers to craft their specifications to optimize safety, performance and cost.
By plotting out its own unique loading chart, the standard will help designers select the proper thickness and type of glass to resist specified loads when writing VIG specifications. In addition, this data will help clarify whether design pressures, edge support and deflection requirements meet building code requirements.
Why is New Testing Necessary?
The industry cannot simply rely on existing insulating glass charts and standards because VIG technology functions differently in construction, behavior and performance. Unlike conventional insulating glass units, VIG utilizes a vacuum cavity and a system of internal support pillars that create a unique structural response under load. As a result, performance characteristics observed in traditional insulating glass cannot automatically be applied to VIG products.
Once these data sets are completed and VIG’s performance characteristics are better understood, ASTM’s WK83445 VIG performance standard can proceed and FGIA’s IGMA TB-2600 Vacuum Insulating Glass document work can resume.
The former will standardize testing and evaluation procedures, establish industry-accepted design methodologies and provide consistent product qualification requirements. It will also enable manufacturers, specifiers, code officials and building owners to work from the same set of rules.
Meanwhile, the new standard will help manufacturers understand and evaluate the benefits and intended use of VIG systems. The testing data generated through this project will also provide the technical foundation needed to develop future VIG design guidance and loading charts similar to those available for conventional glass products. These resources will help designers and specifiers make informed decisions based on industry-supported performance data rather than assumptions or proprietary calculations.
The Testing Process
As part of this testing process, FGIA and NGA have gathered samples from three VIG manufacturers in three different sizes and is in the process of performing uniform load resistance testing per ASTM E997, “Standard Test Method for Evaluating Glass Breakage Probability Under the Influence of Uniform Static Loads by Proof Load Testing,” to failure per ASTM E998 testing for structural performance.
The testing process includes two types of monolithic control glass samples, with one 38-by-76-inch specimen type fabricated from 8-mm annealed glass and one 38-by-76-inch specimen type fabricated from 8-mm fully tempered glass.
The VIG samples are 38-by-76-inch, 58-by-58-inch and 58-by-96-inch. The edges are four-sided, simply supported, with a 4-mm + 4-mm thickness configuration, approximately 8 mm thick. In total, 55 samples will be tested and deflection measurements will be recorded for center-of-glass deflection versus test pressure.
Moving Forward
While VIG is a very promising technology, market adoption is taking time. This type of reliable load resistance data will help designers more confidently specify VIG, enable building officials to more comfortably approve applications, encourage manufacturers to continue developing the technology and enable building owners to achieve both energy-efficiency and safety objectives. Because the project includes specimens from three manufacturers and multiple sizes, the resulting data set will provide a broader understanding of VIG performance across the industry. Ultimately, the work will help establish safe design limits, increase confidence in VIG specifications and support the continued advancement of this innovative glazing technology.